The façade is the array.

A curtain-wall panel that generates. 880 × 480 mm, 88 W, 208 W/m² — and a colour, texture and transmittance the architect can actually specify.

What it is

Not a module bolted to a wall.

Conventional BIPV is a compromise: a framed module hung in front of a building, with the architect asked to design around it. This is the other direction — the generating unit becomes the cladding element, so the elevation is designed first and the electrical layer is built into it.

Two glass panes, 2.0 mm each, laminated around 210 × 105 mm mono cells. Front and rear glass means the panel behaves as a building product — impact, fire and wind-load performance are decided at the glass, not added afterwards. The busbar-free cell process carries over from our main line, which is why the efficiency holds at 20.83% in a format this small.

The colour is not a film. Ink-blue and gilded gold are produced in the glass build-up, so the finish does not delaminate, fade at the edges, or change the panel's fire classification.

Electrical & physical

XSXN-04
ParameterValue
ModelXSXN-04
Maximum power Pmax88 W
Module efficiency20.83%
Output per m²208 W/m²
Dimensions (mm)880 × 480
Maximum system voltage1500 V
Cell typeMono 210 × 105
Front / rear glass2.0 mm tempered
EncapsulationEVA film
Busbar ends4 mm / 4 mm
ColourInk blue / gilded gold
Colour optionsCustom to project

Vmp, Imp, Voc and Isc are issued with the project datasheet — they depend on the glass build-up and the colour layer selected. Do not size the string from the headline power alone.

Customisation

Three variables the architect controls.

Every one of them costs output. That trade is the whole design conversation on a BIPV project, and it is better had before the façade drawings are frozen.

01 / COLOUR

Ink blue or gilded gold

Standard finishes are ink blue and gilded gold, produced in the glass rather than applied as a coating. Other colours available to project, subject to a minimum order and a colour-match sample.

1.5 × 1.5 m sampleMOQ on request

02 / TRANSMITTANCE

How much daylight

Cell spacing sets the transparent fraction. More glass means more daylight and less generation per square metre — a genuine architectural decision, not a technical detail.

Spacing to specOutput traded

03 / TEXTURE

Surface and pattern

Etched, frosted or patterned front glass changes how the façade reads at different times of day. It also changes reflectance, which affects both glare and yield.

EtchedPatterned

Engineering reality

What a vertical façade actually produces.

A south-facing vertical plane receives far less annual irradiation than a tilted array at the same site — and much more in winter than in summer. BIPV projects fail on yield expectations more often than on hardware.

We will run the orientation study before quoting. Send the building elevation drawings and the site coordinates. If the façade is north-facing or heavily shaded, we will say so rather than sell panels into a bad elevation.
  • 01

    Building code comes first

    The panel must satisfy fire, impact and wind-load requirements before it generates anything. Glass build-up and fixing detail are set by the façade engineer, not by us.

  • 02

    Cavity temperature cuts output

    A ventilated rainscreen behind the panel keeps the cell cooler. A sealed cavity traps heat and costs yield all summer — a detail worth arguing about at design stage.

  • 03

    Cabling belongs in the detail

    Every panel needs a connection route that is not visible on the elevation. Junction space has to be designed into the mullion, not retrofitted on site.

  • 04

    String design is not standard

    Facade arrays are small, irregular and split across orientations. Expect more MPPT channels and shorter strings than a roof array of the same capacity.

Applications

Where a generating envelope pays for itself.

BIPV is a cladding decision with an energy return attached. It makes sense where the façade is being replaced anyway, or where the building's sustainability case is being audited.

Curtain wall

Unitised and stick systems

Atrium and skylight

Transmittance-controlled

Canopy and shading

Horizontal and louvre

Balustrade

Laminated safety build-up

Retrofit overlay

On existing elevations

Signature elements

Feature walls and entries

Send the elevation drawings.

Site coordinates, orientation, glazing ratio and the cladding system you are using. We will come back with a panel layout, an expected annual yield and the constraint list — including the ones that argue against the project.